PUREAIRE MONITORING SYSTEMS
  • Blog
  • Products
  • About
  • Contact
  • Blog

Nitrogen Use in the Fabrication of MEMS

10/12/2020

0 Comments

 
Picture
No, not memes…it’s MEMS.
Background
MEMS (that is, micro-electro-mechanical systems), which are sometimes called micromachines, consist of mechanical and electrical components which work together as a system to attain the functionality necessary for use in smartphones, inkjet printers, medical equipment, fitness trackers, home automation, and automobiles, to list just a few commercial uses. MEMS are manufactured through a process called microfabrication, and the dimensions of MEMS can range in size from less than a micrometer (a size smaller than the width of a human hair), to several millimeters.
Just a Few of the Many Commercial and Industrial Applications of MEMS
MEMS are what enable a smartphone screen to rotate from landscape to portrait and back again, and they can make a phone act as a steering wheel, allowing gamers to “drive” around obstacles in a racing video game. Thanks to MEMS, smartphones are used for navigation, as a digital wallet and, by using a fingerprint, provide for a secure way to log into a phone’s applications.
The healthcare industry uses MEMS in, among other things, pressure sensor applications, including disposable blood pressure monitors, measuring intrauterine pressure during childbirth,  and monitoring breathing of patients on ventilators.
Wearable fitness trackers utilize MEMS containing accelerometers and gyroscopes in combination with global positioning systems (GPS) to count a user’s steps and pace, and to show a user’s route.
Homeowners enjoy the convenience of regulating air quality and temperature, and  activating lights, and security systems, that MEMS technology provides. MEMS sensors can be programmed to adjust air circulation and thermostats based on the results of readings taken. Home security systems use MEMS-based motion sensors to send an alert if there is a change in movement or unusual vibrations due to a forced entry.
Automobile manufacturers utilize MEMS technology in a host of applications, including assessing vehicle impact for crash detection and airbag deployment, as well as in tire pressure monitoring systems, vehicle dynamic controls (which help drivers regain control when their vehicles begin to skid), voice activation systems, and climate control inside the car.
Nitrogen Usage in MEMS Fabrication
The fabrication of MEMS devices is conducted in process chambers (low pressure, vacuum, temperature-controlled atmospheres) inside cleanrooms (hermetically sealed, fully automated environments).
All process/vacuum chambers, machinery, and cleanrooms must be free of contamination. Dust, airborne particles, aerosols, chemical vapors, and residual gases created or used during production must be removed from the environment to protect the integrity of the devices being manufactured.
Nitrogen (N), an odorless, colorless, oxygen-depleting inert gas, is a critical component in creating and maintaining the sterile environment necessary for MEMS fabrication. MEMS fabrication plants typically use large amounts of nitrogen to sterilize manufacturing environments, remove residual gases from chambers and gas lines, and to purge process chambers of impurities between process steps.
Oxygen Analyzers Protect the Integrity of MEMS Fabrication
Manufacturing employees must constantly monitor nitrogen levels within process chambers and clean rooms, in order to protect these areas from impurities that could impair the quality and reliability of the MEMS being produced, and to guard against nitrogen leaks that could lead to failure of the sterile environment, likewise compromising the integrity of the MEMS devices.
Utilizing high-quality oxygen analyzers allows MEMS fabrication personnel to track nitrogen levels in work areas. The oxygen analyzer sensor should be placed inside process/vacuum chambers and clean rooms to measure and control oxygen levels. Best practice calls for oxygen deficiency analyzers to be installed anywhere there is a risk of gas leaks. As such, oxygen analyzers should be placed wherever nitrogen is stored, and in all areas where nitrogen is used.
PureAire and Oxygen Analyzers
PureAire Monitoring Systems’ Trace Oxygen Analyzer 0-1000ppm has a remote sensor that, with the use of a KF type vacuum fitting, mounts directly into a process/vacuum chamber, to continuously monitor the efficiency of the nitrogen gas used therein.
Our Trace Oxygen Analyzer measures oxygen 24/7, with no time-consuming maintenance required. PureAire’s monitors feature long-lasting zirconium sensors, which are designed to give accurate readings, without calibration, for up to 10 years.
Picture
0 Comments



Leave a Reply.

    1140 Ensell , Lake Zurich IL 60047-6711
    Toll Free: 888.788.8050 • Phone: 847.726.6000
    Fax: 847.726.6051 • Email:[email protected]

    Archives

    May 2024
    April 2024
    March 2024
    September 2023
    July 2023
    June 2023
    April 2023
    November 2022
    September 2022
    July 2022
    April 2022
    January 2022
    November 2021
    August 2021
    June 2021
    May 2021
    March 2021
    February 2021
    December 2020
    November 2020
    October 2020
    August 2020
    November 2019
    October 2019
    July 2019
    June 2019
    May 2019
    April 2019
    February 2019
    January 2019
    December 2018
    October 2018
    September 2018
    August 2018
    May 2018
    March 2018
    February 2018
    January 2018
    December 2017
    November 2017
    October 2017
    August 2017
    June 2017
    May 2017
    March 2017
    January 2017
    December 2016
    November 2016
    October 2016
    September 2016
    August 2016
    July 2016
    June 2016
    May 2016
    April 2016
    March 2016
    February 2016
    November 2015
    October 2015
    September 2015
    August 2015
    June 2015

    Categories

    All
    3D Metal Printing
    3D Printing
    Additive Manufacturing
    Airlines
    Alternative Fuel Vehicles
    Argon
    Beyond Meat
    Breweries
    Build Chamber
    Butane
    Cannabinoids
    Cannabis
    Cannabis Extraction
    Carbon Capture
    Carbon Dioxide
    Carbon Dioxide Monitor
    Cbd
    CBD Oil
    Char
    Charring
    Chlorine
    Chlorine Gas
    Chlorine Safety
    CL2
    CNG
    CO2
    Cold Chain
    Combustible
    Combustible Gas
    Combustible Gas Monitor
    Compressed Gases
    Corrosion
    Covid-19 Vaccine
    Cryochamber
    Cryogenic
    Cryogenic Facilities
    Cryogenic Gases
    Cryopreservation
    Cryopump
    Cryo Spa
    Cryostorage
    Cryotherapy
    Disinfectant
    Disinfecting
    Disinfection
    Dry Ice
    Earthly Labs
    Eggs
    Electrolyte
    Embryos
    Ethanol
    Ethyl Alcohol
    Ethylene
    EtO
    Explosion Proof
    Extraction
    Fertility Clinic
    Flammable
    Flash-frozen
    Food
    Food Processing
    Food Spoilage
    Freeze-dried
    Freezer
    Gas
    Gas Detection
    Gas Detector
    Gas Detectors
    Gases
    Gas Leak
    Gas Leaks
    Gas Mixture
    Grow
    H2o2
    Hand Sanitizer
    Helium
    Heme
    Hopper
    Hot Melt Adhesive
    Hot Melt Foam Adhesive
    How To Monitor Oxygen Levels In A Room
    Hydrocarbon
    Hydrocarbon Solvent Extraction
    Hydrogen Fuel
    Hydrogen Peroxide
    Hydrogen Peroxide Vapor
    Impossible Foods
    Inert Gas
    In Vitro Fertilization
    IVF
    James Webb Telescope
    Laboratory Safety
    Leak Detection
    Leghemoglobin
    Lel
    Li-ion Battery
    Liquid Helium
    Liquid Nitrogen
    Liquid Nitrogen Leak
    Lithium-ion Battery
    LN2
    LNG
    Low Oxygen Environments
    Magnetic Resonance
    Medical Device
    Melt Tank
    Metal Powders
    Modified Atmosphere Packaging
    Monitoring
    Mri
    Mri O2 Monitor
    N2
    N95 Masks
    N95 Respirators
    Natural Gas
    Nema 4
    Nitrogen
    Nitrogen Blanketing
    Nitrogen Generator
    Nmr
    O
    O2
    O2/CO2 Monitor
    O2 Dry Ice
    Off-gas
    Osha
    Oxidation
    Oxide
    Oxygen
    Oxygen Analyzer
    Oxygen/carbon Dioxide Monitor
    Oxygen Deficiency
    Oxygen Deficiency Monitor
    Oxygen Deficiency Monitors
    Oxygen Depleting
    Oxygen Depletion
    Oxygen Detection
    Oxygen Displacement
    Oxygen Levels
    Oxygen Monitor
    Oxygen Monitoring
    Oxygen Monitors
    Pharmaceutical
    Plant Based Meat
    Porosity
    PPE
    Propane
    PureAire
    Sample Draw Oxygen Monitor
    Smart Sensor Cell
    Sterilization
    Sterilizing
    Superconductivity
    Surgical Devices
    Tank Blanketing
    Terpenes
    Thc
    Thermal Runaway
    Thermal Vacuum Chamber
    Titanium
    Trace Oxygen
    Tunnel Freezer
    Universal Gas Detector
    Vaccine
    Vaccine Storage
    Vaccine Transport
    Water Resistant
    Whole Body Cryotherapy
    Zirconium Oxide

Proudly powered by Weebly